Hitachi Aircon Error Codes

Reference table for common Hitachi codes. Use it to understand likely meaning, typical causes, and context before booking.

Before you use this tool

This is a guidance table, not a model-exact diagnosis. The same code can differ by series, controller, and model year. Use this page to narrow next steps, then verify with model sticker details.

Safety warning

Stop using the unit and contact a technician if the breaker trips repeatedly, you smell burning, see sparks, hear loud electrical buzzing, or water is leaking from places it normally should not.

Hitachi code table

Includes common SG residential split-system codes with likely meaning and typical causes.

01Indoor

Indoor safety device activated

Typical causes

  • Drain protection or float-switch trigger
  • Indoor fan or airflow-related protection trip
  • Indoor control circuit fault
02Outdoor

Outdoor safety/high-pressure device activated

Typical causes

  • Outdoor high-pressure switch trip
  • Condenser airflow restriction
  • Outdoor protection circuit activation
03Communication

Abnormal transmission between indoor and outdoor units

Typical causes

  • Interconnection wiring fault or poor contact
  • Communication PCB fault at indoor or outdoor unit
  • Power disturbance affecting serial communication
05Inverter

Phase signal detection abnormal

Typical causes

  • Phase pickup/synchronization circuit fault
  • Inverter board signal processing issue
  • Power supply waveform abnormality
06Inverter

Inverter voltage abnormal (too low/high)

Typical causes

  • Undervoltage or overvoltage at outdoor inverter
  • DC bus voltage instability
  • Inverter PCB power-stage fault
07System

Discharge superheat control abnormal

Typical causes

  • Refrigerant flow instability
  • Expansion control issue
  • Compressor loading outside normal envelope
08Inverter

Compressor discharge temperature too high

Typical causes

  • Compressor thermal overload
  • Poor heat rejection at condenser
  • Sensor/control drift causing overheating protection
13Sensor

Indoor heat-exchanger liquid-pipe thermistor abnormal

Typical causes

  • Liquid-pipe thermistor open or short circuit
  • Loose sensor connector
  • Indoor PCB input channel fault
14Sensor

Indoor heat-exchanger gas-pipe thermistor abnormal

Typical causes

  • Gas-pipe thermistor open or short circuit
  • Sensor harness damage or poor contact
  • Control PCB thermistor sensing fault
15Sensor

Fresh-air/air-temperature thermistor abnormal

Typical causes

  • Outdoor/fresh-air thermistor failure
  • Sensor wiring disconnection
  • PCB thermistor read error
19Indoor

Indoor fan motor protection activated

Typical causes

  • Indoor fan motor lock or overload
  • Fan drive circuit issue on indoor PCB
  • Wiring/connector fault to fan motor
20Sensor

Compressor discharge thermistor abnormal

Typical causes

  • Discharge thermistor open or short
  • Loose thermistor connector
  • Outdoor control board sensing fault
22Sensor

Outdoor ambient thermistor abnormal

Typical causes

  • Outdoor ambient thermistor open/short
  • Sensor connector corrosion or looseness
  • Outdoor PCB sensor input issue
24Sensor

Evaporating-temperature thermistor abnormal in heating

Typical causes

  • Evaporating thermistor open or short
  • Sensor installation or contact issue
  • Heating-cycle control board sensor error
35System

Incorrect indoor unit number/capacity setting

Typical causes

  • Indoor-outdoor addressing mismatch
  • Incorrect combined indoor capacity setup
  • Installation/configuration error after replacement
38Inverter

Outdoor protective circuit abnormal

Typical causes

  • Outdoor protection circuit component fault
  • Inverter board fault
  • Protection logic triggered by abnormal electrical load
41Outdoor

Cooling overload with high-pressure protection

Typical causes

  • Condenser airflow restriction
  • Outdoor fan underperformance
  • System high-pressure condition during cooling
42Outdoor

Heating overload with high-pressure protection

Typical causes

  • High refrigerant pressure during heating
  • Outdoor heat-exchanger airflow limitation
  • Outdoor fan or control fault
45Outdoor

High-pressure increase protection activated

Typical causes

  • Rapid pressure rise in refrigerant circuit
  • Condenser heat rejection problem
  • Outdoor control/protection trip
47Outdoor

Low-suction-pressure protection active

Typical causes

  • Very low suction pressure in refrigerant circuit
  • Refrigerant shortage or restriction
  • Protection logic activation to prevent damage
48Inverter

Instantaneous overcurrent protection (inverter)

Typical causes

  • Inverter current spike beyond threshold
  • Compressor electrical stress
  • Power module or drive-circuit fault
51Sensor

Current sensor circuit abnormal

Typical causes

  • Faulty current sensor
  • Sensor circuit wiring fault
  • Outdoor PCB current-measurement fault
53Inverter

IPM/transistor module protection activated

Typical causes

  • Inverter transistor module fault
  • IPM protection triggered by abnormal load
  • Outdoor drive circuit abnormality
57Outdoor

Outdoor DC fan motor protection abnormal

Typical causes

  • Outdoor fan motor output drop or lock
  • Fan driver fault on outdoor board
  • Mechanical resistance at fan assembly
B1System

Incorrect unit and refrigerant-cycle number setting

Typical causes

  • Wrong unit addressing setup
  • Refrigerant cycle number mismatch
  • Configuration error after installation or PCB replacement
E0System

EEPROM or indoor control memory error

Typical causes

  • Corrupted indoor control memory data
  • Indoor PCB failure
  • Power interruption during control write cycle
E1Outdoor

High-pressure protection activated

Typical causes

  • Blocked condenser airflow at outdoor unit
  • Outdoor fan underperforming or stalled
  • High refrigerant pressure from overcharge or restriction
E2Indoor

Indoor coil freeze protection active

Typical causes

  • Restricted indoor airflow from dirty filter or coil
  • Low refrigerant condition
  • Indoor fan or thermistor control issue
E3Outdoor

Low-pressure protection activated

Typical causes

  • Refrigerant leak or undercharge
  • Refrigeration circuit restriction
  • Pressure sensor or control fault
E4Inverter

Compressor overheating protection

Typical causes

  • High compressor thermal load
  • Poor condenser heat rejection
  • Compressor or inverter drive abnormality
E5Inverter

Overcurrent protection active

Typical causes

  • Compressor current draw above limit
  • Inverter power module stress
  • Power supply instability
E6Communication

Indoor-outdoor communication error

Typical causes

  • Loose or damaged interconnection cable
  • Terminal contact corrosion or loose connection
  • Indoor or outdoor PCB communication circuit fault
F1Sensor

Indoor temperature sensor fault

Typical causes

  • Room thermistor open or short circuit
  • Loose sensor harness connection
  • Indoor PCB sensor input fault
F2Sensor

Evaporator coil sensor fault

Typical causes

  • Evaporator thermistor open or short circuit
  • Sensor wire damage or connector looseness
  • Indoor PCB sensing circuit issue

Not sure how to interpret your Hitachi code?

Share the code and your model sticker. We'll advise your next step before any work is approved.