Midea Aircon Blinking Light Patterns

Reference table for common Midea blink patterns. Use this to identify likely fault classes and narrow what to check next.

Before you use this tool

This is a blink-pattern guidance table, not a model-exact diagnosis. Pattern meaning can vary by controller and series. If your controller shows a direct code (for example `CH21`, `U4`, `E6`), use the error-code guide for a faster match.

Safety warning

Stop using the unit and contact a technician if the breaker trips repeatedly, you smell burning, see sparks, hear loud electrical buzzing, or water is leaking from places it normally should not.

Midea pattern table

Includes common SG residential blinking-light patterns with likely fault classes and typical causes.

Blink count: 1

Operation lamp flashes 1 time repeatedly while timer lamp remains off

EEPROM parameter error indication (fixed-speed table)

Details

Pattern ID: OP_LAMP_1_FLASH_E1_EEPROM

Pattern type: Blink count cycle

Blink count: 1

Service code (reference only): E1

Category: System

Indicator: Indoor unit

LEDs: OPERATION

Typical causes

  • EEPROM parameter corruption
  • Indoor control memory fault
  • PCB data-read error
Blink count: 2

Operation lamp flashes 2 times repeatedly while timer lamp remains off

Indoor-outdoor communication fault indication (inverter table)

Details

Pattern ID: OP_LAMP_2_FLASH_E1_COMM

Pattern type: Blink count cycle

Blink count: 2

Service code (reference only): E1

Category: Communication

Indicator: Indoor unit

LEDs: OPERATION

Typical causes

  • Indoor-outdoor communication loss
  • Interconnection wiring issue
  • Indoor or outdoor PCB communication fault
Blink count: 5

Operation lamp flashes 5 times repeatedly while timer lamp remains off

Indoor room temperature sensor (T1) fault indication

Details

Pattern ID: OP_LAMP_5_FLASH_E4_ROOM_SENSOR

Pattern type: Blink count cycle

Blink count: 5

Service code (reference only): E4

Category: Sensor

Indicator: Indoor unit

LEDs: OPERATION

Typical causes

  • T1 sensor open/short
  • Sensor wiring/connector fault
  • Indoor PCB sensor-input issue
Blink count: 6

Operation lamp flashes 6 times repeatedly while timer lamp remains off

Evaporator coil temperature sensor (T2) fault indication

Details

Pattern ID: OP_LAMP_6_FLASH_E5_COIL_SENSOR

Pattern type: Blink count cycle

Blink count: 6

Service code (reference only): E5

Category: Sensor

Indicator: Indoor unit

LEDs: OPERATION

Typical causes

  • T2 sensor open/short
  • Sensor harness fault
  • Indoor control-board input fault
Blink count: 8pauses ~1 second, then repeats

Outdoor module LED5 stays ON while LED4 flashes 8 times, pauses ~1 second, then repeats

Inverter module protection indication on outdoor PCB LEDs

Details

Pattern ID: OUTDOOR_LED4_8_FLASH_XL0

Pattern type: Blink count cycle

Blink count: 8

Service code (reference only): xL0

Category: Inverter

Indicator: Outdoor unit

LEDs: LED4, LED5

Typical causes

  • Inverter module protection trigger
  • Outdoor power-stage stress
  • Drive module abnormality
Blink count: 9pauses ~1 second, then repeats

Outdoor module LED5 stays ON while LED4 flashes 9 times, pauses ~1 second, then repeats

DC bus low-voltage protection indication on outdoor PCB LEDs

Details

Pattern ID: OUTDOOR_LED4_9_FLASH_XL1

Pattern type: Blink count cycle

Blink count: 9

Service code (reference only): xL1

Category: System

Indicator: Outdoor unit

LEDs: LED4, LED5

Typical causes

  • DC bus low-voltage event
  • Power supply instability
  • Outdoor drive/power circuit fault
Blink count: 10pauses ~1 second, then repeats

Outdoor module LED5 stays ON while LED4 flashes 10 times, pauses ~1 second, then repeats

DC bus high-voltage protection indication on outdoor PCB LEDs

Details

Pattern ID: OUTDOOR_LED4_10_FLASH_XL2

Pattern type: Blink count cycle

Blink count: 10

Service code (reference only): xL2

Category: System

Indicator: Outdoor unit

LEDs: LED4, LED5

Typical causes

  • DC bus over-voltage event
  • Power surge condition
  • Outdoor power-stage abnormality
Blink count: 12pauses ~1 second, then repeats

Outdoor module LED5 stays ON while LED4 flashes 12 times, pauses ~1 second, then repeats

MCE/inverter control error indication on outdoor PCB LEDs

Details

Pattern ID: OUTDOOR_LED4_12_FLASH_XL4

Pattern type: Blink count cycle

Blink count: 12

Service code (reference only): xL4

Category: Inverter

Indicator: Outdoor unit

LEDs: LED4, LED5

Typical causes

  • Inverter control error (MCE)
  • Drive command/frequency mismatch
  • Outdoor module control fault

Not sure how to read your Midea blink pattern?

Send a short blink video and your model sticker. We'll advise the next step before any work is recommended.