Filter cleaning reminder
Maintenance/status logic from controller · Temporary operating state during protection or cleaning
Learn what common Samsung error codes mean, what typically causes them, and whether they need urgent attention.
This is a guidance table, not a model-exact diagnosis. The same code can differ by series, controller, and model year. Use this page to narrow next steps, then verify with model sticker details.
Safety Warning
Stop using the unit and contact a technician if the breaker trips repeatedly, you smell burning, see sparks, hear loud electrical buzzing, or water is leaking from places it normally should not.
Filter cleaning reminder
Maintenance/status logic from controller · Temporary operating state during protection or cleaning
Mode change/mismatch error
Configuration or addressing mismatch between units · EEPROM/option data error in control board memory · System control logic fault · Power interruption affecting startup sequence
Auto-cleaning status code
Maintenance/status logic from controller · Temporary operating state during protection or cleaning
Auto-defrost in progress
Maintenance/status logic from controller · Temporary operating state during protection or cleaning
Indoor fan motor abnormal
Indoor fan motor lock, wear, or winding fault · Indoor PCB fan-drive or control output fault · Loose indoor motor harness or connector contact · Severe airflow restriction from dirty filter/coil
Indoor-outdoor communication abnormal
Loose or damaged interconnection cable between indoor and outdoor units · Poor terminal contact or corroded wiring joints · Indoor PCB or outdoor PCB communication circuit fault · Power supply instability after restart or outage
Indoor heat exchanger temperature sensor abnormal
Thermistor or sensor open/short circuit · Loose sensor connector or harness damage · Sensor drift from heat/moisture exposure · PCB sensor input channel fault
Outdoor heat exchanger temperature sensor abnormal
Thermistor or sensor open/short circuit · Loose sensor connector or harness damage · Sensor drift from heat/moisture exposure · PCB sensor input channel fault
Outdoor unit abnormality (model-dependent)
Outdoor fan/airflow or pressure protection trigger · Condenser airflow restriction or heavy dirt loading · Refrigerant pressure imbalance, restriction, or undercharge/overcharge · Outdoor PCB protection circuit fault
Indoor unit communication error
Loose or damaged interconnection cable between indoor and outdoor units · Poor terminal contact or corroded wiring joints · Indoor PCB or outdoor PCB communication circuit fault · Power supply instability after restart or outage
Indoor-outdoor communication error
Loose or damaged interconnection cable between indoor and outdoor units · Poor terminal contact or corroded wiring joints · Indoor PCB or outdoor PCB communication circuit fault · Power supply instability after restart or outage
Indoor-outdoor communication error
Loose or damaged interconnection cable between indoor and outdoor units · Poor terminal contact or corroded wiring joints · Indoor PCB or outdoor PCB communication circuit fault · Power supply instability after restart or outage
Indoor-outdoor communication error
Loose or damaged interconnection cable between indoor and outdoor units · Poor terminal contact or corroded wiring joints · Indoor PCB or outdoor PCB communication circuit fault · Power supply instability after restart or outage
Indoor-outdoor communication error
Loose or damaged interconnection cable between indoor and outdoor units · Poor terminal contact or corroded wiring joints · Indoor PCB or outdoor PCB communication circuit fault · Power supply instability after restart or outage
Indoor-outdoor communication error
Loose or damaged interconnection cable between indoor and outdoor units · Poor terminal contact or corroded wiring joints · Indoor PCB or outdoor PCB communication circuit fault · Power supply instability after restart or outage
Indoor-outdoor communication error
Loose or damaged interconnection cable between indoor and outdoor units · Poor terminal contact or corroded wiring joints · Indoor PCB or outdoor PCB communication circuit fault · Power supply instability after restart or outage
Indoor room temperature sensor open/short
Thermistor or sensor open/short circuit · Loose sensor connector or harness damage · Sensor drift from heat/moisture exposure · PCB sensor input channel fault
Indoor heat exchanger sensor open/short
Thermistor or sensor open/short circuit · Loose sensor connector or harness damage · Sensor drift from heat/moisture exposure · PCB sensor input channel fault
Indoor heat exchanger sensor 2 open/short
Thermistor or sensor open/short circuit · Loose sensor connector or harness damage · Sensor drift from heat/moisture exposure · PCB sensor input channel fault
Indoor heat exchanger sensor 3 open/short
Thermistor or sensor open/short circuit · Loose sensor connector or harness damage · Sensor drift from heat/moisture exposure · PCB sensor input channel fault
Indoor heat exchanger sensor 4 open/short
Thermistor or sensor open/short circuit · Loose sensor connector or harness damage · Sensor drift from heat/moisture exposure · PCB sensor input channel fault
Indoor heat exchanger sensor 5 open/short
Thermistor or sensor open/short circuit · Loose sensor connector or harness damage · Sensor drift from heat/moisture exposure · PCB sensor input channel fault
Indoor heat exchanger sensor 6 open/short
Thermistor or sensor open/short circuit · Loose sensor connector or harness damage · Sensor drift from heat/moisture exposure · PCB sensor input channel fault
Indoor heat exchanger sensor 7 open/short
Thermistor or sensor open/short circuit · Loose sensor connector or harness damage · Sensor drift from heat/moisture exposure · PCB sensor input channel fault
Indoor heat exchanger sensor 8 open/short
Thermistor or sensor open/short circuit · Loose sensor connector or harness damage · Sensor drift from heat/moisture exposure · PCB sensor input channel fault
Indoor heat exchanger sensor 9 open/short
Thermistor or sensor open/short circuit · Loose sensor connector or harness damage · Sensor drift from heat/moisture exposure · PCB sensor input channel fault
Indoor heat exchanger sensor 10 open/short
Thermistor or sensor open/short circuit · Loose sensor connector or harness damage · Sensor drift from heat/moisture exposure · PCB sensor input channel fault
Indoor fan motor error
Indoor fan motor lock, wear, or winding fault · Indoor PCB fan-drive or control output fault · Loose indoor motor harness or connector contact · Severe airflow restriction from dirty filter/coil
Indoor fan motor feedback error
Indoor fan motor lock, wear, or winding fault · Indoor PCB fan-drive or control output fault · Loose indoor motor harness or connector contact · Severe airflow restriction from dirty filter/coil
Indoor fan motor 2 error
Indoor fan motor lock, wear, or winding fault · Indoor PCB fan-drive or control output fault · Loose indoor motor harness or connector contact · Severe airflow restriction from dirty filter/coil
Indoor fan motor 2 feedback error
Indoor fan motor lock, wear, or winding fault · Indoor PCB fan-drive or control output fault · Loose indoor motor harness or connector contact · Severe airflow restriction from dirty filter/coil
Indoor fan motor 3 error
Indoor fan motor lock, wear, or winding fault · Indoor PCB fan-drive or control output fault · Loose indoor motor harness or connector contact · Severe airflow restriction from dirty filter/coil
Indoor fan motor 3 feedback error
Indoor fan motor lock, wear, or winding fault · Indoor PCB fan-drive or control output fault · Loose indoor motor harness or connector contact · Severe airflow restriction from dirty filter/coil
Outdoor fan motor 1 error
Outdoor fan/airflow or pressure protection trigger · Condenser airflow restriction or heavy dirt loading · Refrigerant pressure imbalance, restriction, or undercharge/overcharge · Outdoor PCB protection circuit fault
Outdoor fan motor 1 feedback error
Outdoor fan/airflow or pressure protection trigger · Condenser airflow restriction or heavy dirt loading · Refrigerant pressure imbalance, restriction, or undercharge/overcharge · Outdoor PCB protection circuit fault
Outdoor fan motor 2 error
Outdoor fan/airflow or pressure protection trigger · Condenser airflow restriction or heavy dirt loading · Refrigerant pressure imbalance, restriction, or undercharge/overcharge · Outdoor PCB protection circuit fault
Outdoor fan motor 2 feedback error
Outdoor fan/airflow or pressure protection trigger · Condenser airflow restriction or heavy dirt loading · Refrigerant pressure imbalance, restriction, or undercharge/overcharge · Outdoor PCB protection circuit fault
Indoor unit communication/disconnection error
Loose or damaged interconnection cable between indoor and outdoor units · Poor terminal contact or corroded wiring joints · Indoor PCB or outdoor PCB communication circuit fault · Power supply instability after restart or outage
Indoor unit communication/disconnection error
Loose or damaged interconnection cable between indoor and outdoor units · Poor terminal contact or corroded wiring joints · Indoor PCB or outdoor PCB communication circuit fault · Power supply instability after restart or outage
Indoor unit communication/disconnection error
Loose or damaged interconnection cable between indoor and outdoor units · Poor terminal contact or corroded wiring joints · Indoor PCB or outdoor PCB communication circuit fault · Power supply instability after restart or outage
Indoor unit communication/disconnection error
Loose or damaged interconnection cable between indoor and outdoor units · Poor terminal contact or corroded wiring joints · Indoor PCB or outdoor PCB communication circuit fault · Power supply instability after restart or outage
Indoor unit communication/disconnection error
Loose or damaged interconnection cable between indoor and outdoor units · Poor terminal contact or corroded wiring joints · Indoor PCB or outdoor PCB communication circuit fault · Power supply instability after restart or outage
Indoor unit communication/disconnection error
Loose or damaged interconnection cable between indoor and outdoor units · Poor terminal contact or corroded wiring joints · Indoor PCB or outdoor PCB communication circuit fault · Power supply instability after restart or outage
Indoor unit communication/disconnection error
Loose or damaged interconnection cable between indoor and outdoor units · Poor terminal contact or corroded wiring joints · Indoor PCB or outdoor PCB communication circuit fault · Power supply instability after restart or outage
Indoor unit communication/disconnection error
Loose or damaged interconnection cable between indoor and outdoor units · Poor terminal contact or corroded wiring joints · Indoor PCB or outdoor PCB communication circuit fault · Power supply instability after restart or outage
Indoor EEPROM option error
Configuration or addressing mismatch between units · EEPROM/option data error in control board memory · System control logic fault · Power interruption affecting startup sequence
Indoor EEPROM option error
Configuration or addressing mismatch between units · EEPROM/option data error in control board memory · System control logic fault · Power interruption affecting startup sequence
Indoor EEPROM option error
Configuration or addressing mismatch between units · EEPROM/option data error in control board memory · System control logic fault · Power interruption affecting startup sequence
Indoor EEPROM option error
Configuration or addressing mismatch between units · EEPROM/option data error in control board memory · System control logic fault · Power interruption affecting startup sequence
Indoor EEPROM option error
Configuration or addressing mismatch between units · EEPROM/option data error in control board memory · System control logic fault · Power interruption affecting startup sequence
Indoor EEPROM option error
Configuration or addressing mismatch between units · EEPROM/option data error in control board memory · System control logic fault · Power interruption affecting startup sequence
Indoor EEPROM option error
Configuration or addressing mismatch between units · EEPROM/option data error in control board memory · System control logic fault · Power interruption affecting startup sequence
Indoor tracking/configuration error
Configuration or addressing mismatch between units · EEPROM/option data error in control board memory · System control logic fault · Power interruption affecting startup sequence
Indoor option setting error
Configuration or addressing mismatch between units · EEPROM/option data error in control board memory · System control logic fault · Power interruption affecting startup sequence
Indoor option setting error
Configuration or addressing mismatch between units · EEPROM/option data error in control board memory · System control logic fault · Power interruption affecting startup sequence
Indoor option setting error
Configuration or addressing mismatch between units · EEPROM/option data error in control board memory · System control logic fault · Power interruption affecting startup sequence
Outdoor temperature sensor open/short
Thermistor or sensor open/short circuit · Loose sensor connector or harness damage · Sensor drift from heat/moisture exposure · PCB sensor input channel fault
Indoor-outdoor communication error
Loose or damaged interconnection cable between indoor and outdoor units · Poor terminal contact or corroded wiring joints · Indoor PCB or outdoor PCB communication circuit fault · Power supply instability after restart or outage
Indoor-outdoor communication error
Loose or damaged interconnection cable between indoor and outdoor units · Poor terminal contact or corroded wiring joints · Indoor PCB or outdoor PCB communication circuit fault · Power supply instability after restart or outage
Indoor-outdoor communication error
Loose or damaged interconnection cable between indoor and outdoor units · Poor terminal contact or corroded wiring joints · Indoor PCB or outdoor PCB communication circuit fault · Power supply instability after restart or outage
Indoor-outdoor communication error
Loose or damaged interconnection cable between indoor and outdoor units · Poor terminal contact or corroded wiring joints · Indoor PCB or outdoor PCB communication circuit fault · Power supply instability after restart or outage
Indoor-outdoor communication error
Loose or damaged interconnection cable between indoor and outdoor units · Poor terminal contact or corroded wiring joints · Indoor PCB or outdoor PCB communication circuit fault · Power supply instability after restart or outage
Indoor-outdoor communication error
Loose or damaged interconnection cable between indoor and outdoor units · Poor terminal contact or corroded wiring joints · Indoor PCB or outdoor PCB communication circuit fault · Power supply instability after restart or outage
Outdoor ambient temperature sensor open/short
Thermistor or sensor open/short circuit · Loose sensor connector or harness damage · Sensor drift from heat/moisture exposure · PCB sensor input channel fault
Outdoor condenser temperature sensor open/short
Thermistor or sensor open/short circuit · Loose sensor connector or harness damage · Sensor drift from heat/moisture exposure · PCB sensor input channel fault
Compressor discharge temperature sensor open/short
Thermistor or sensor open/short circuit · Loose sensor connector or harness damage · Sensor drift from heat/moisture exposure · PCB sensor input channel fault
Outdoor temperature sensor abnormal
Thermistor or sensor open/short circuit · Loose sensor connector or harness damage · Sensor drift from heat/moisture exposure · PCB sensor input channel fault
Compressor tracking error
Inverter IPM/power module protection trip · Compressor electrical overload, lock, or start failure · DC bus voltage/current abnormality · Outdoor power-stage or driver circuit fault
Outdoor temperature sensor error
Thermistor or sensor open/short circuit · Loose sensor connector or harness damage · Sensor drift from heat/moisture exposure · PCB sensor input channel fault
Indoor/outdoor operation mode mismatch
Configuration or addressing mismatch between units · EEPROM/option data error in control board memory · System control logic fault · Power interruption affecting startup sequence
Compressor startup abnormal
Inverter IPM/power module protection trip · Compressor electrical overload, lock, or start failure · DC bus voltage/current abnormality · Outdoor power-stage or driver circuit fault
Compressor voltage limit control abnormal
Inverter IPM/power module protection trip · Compressor electrical overload, lock, or start failure · DC bus voltage/current abnormality · Outdoor power-stage or driver circuit fault
Compressor voltage abnormal
Inverter IPM/power module protection trip · Compressor electrical overload, lock, or start failure · DC bus voltage/current abnormality · Outdoor power-stage or driver circuit fault
Compressor rotation abnormal
Inverter IPM/power module protection trip · Compressor electrical overload, lock, or start failure · DC bus voltage/current abnormality · Outdoor power-stage or driver circuit fault
Compressor current sensor abnormal
Thermistor or sensor open/short circuit · Loose sensor connector or harness damage · Sensor drift from heat/moisture exposure · PCB sensor input channel fault
Compressor lock abnormal
Inverter IPM/power module protection trip · Compressor electrical overload, lock, or start failure · DC bus voltage/current abnormality · Outdoor power-stage or driver circuit fault
Compressor overload abnormal
Inverter IPM/power module protection trip · Compressor electrical overload, lock, or start failure · DC bus voltage/current abnormality · Outdoor power-stage or driver circuit fault
Compressor overcurrent abnormal
Inverter IPM/power module protection trip · Compressor electrical overload, lock, or start failure · DC bus voltage/current abnormality · Outdoor power-stage or driver circuit fault
Compressor low-voltage abnormal
Inverter IPM/power module protection trip · Compressor electrical overload, lock, or start failure · DC bus voltage/current abnormality · Outdoor power-stage or driver circuit fault
Compressor high-voltage abnormal
Inverter IPM/power module protection trip · Compressor electrical overload, lock, or start failure · DC bus voltage/current abnormality · Outdoor power-stage or driver circuit fault
Compressor operation abnormal
Inverter IPM/power module protection trip · Compressor electrical overload, lock, or start failure · DC bus voltage/current abnormality · Outdoor power-stage or driver circuit fault
Compressor operation abnormal
Inverter IPM/power module protection trip · Compressor electrical overload, lock, or start failure · DC bus voltage/current abnormality · Outdoor power-stage or driver circuit fault
Inverter IPM overtemperature protection
Thermistor or sensor open/short circuit · Loose sensor connector or harness damage · Sensor drift from heat/moisture exposure · PCB sensor input channel fault
Outdoor current sensor abnormal
Thermistor or sensor open/short circuit · Loose sensor connector or harness damage · Sensor drift from heat/moisture exposure · PCB sensor input channel fault
EEPROM error
Configuration or addressing mismatch between units · EEPROM/option data error in control board memory · System control logic fault · Power interruption affecting startup sequence
Compressor discharge temperature too high
Thermistor or sensor open/short circuit · Loose sensor connector or harness damage · Sensor drift from heat/moisture exposure · PCB sensor input channel fault
System fault
Configuration or addressing mismatch between units · EEPROM/option data error in control board memory · System control logic fault · Power interruption affecting startup sequence
Indoor-outdoor communication error
Loose or damaged interconnection cable between indoor and outdoor units · Poor terminal contact or corroded wiring joints · Indoor PCB or outdoor PCB communication circuit fault · Power supply instability after restart or outage
Outstanding unit quantity/configuration error
Configuration or addressing mismatch between units · EEPROM/option data error in control board memory · System control logic fault · Power interruption affecting startup sequence
Invalid temperature input error
Thermistor or sensor open/short circuit · Loose sensor connector or harness damage · Sensor drift from heat/moisture exposure · PCB sensor input channel fault
Outdoor unit abnormality
Outdoor fan/airflow or pressure protection trigger · Condenser airflow restriction or heavy dirt loading · Refrigerant pressure imbalance, restriction, or undercharge/overcharge · Outdoor PCB protection circuit fault
Not sure how to interpret your Samsung code?
Share the code and your model sticker. We'll advise your next step before any work is approved.
WhatsApp us