General fault indication requiring inspection
Temporary power fluctuation or electrical noise · Startup self-check detected abnormal condition · Underlying fault pending full diagnosis
Learn what common LG error codes mean, what typically causes them, and whether they need urgent attention.
This is a guidance table, not a model-exact diagnosis. The same code can differ by series, controller, and model year. Use this page to narrow next steps, then verify with model sticker details.
Safety Warning
Stop using the unit and contact a technician if the breaker trips repeatedly, you smell burning, see sparks, hear loud electrical buzzing, or water is leaking from places it normally should not.
General fault indication requiring inspection
Temporary power fluctuation or electrical noise · Startup self-check detected abnormal condition · Underlying fault pending full diagnosis
Indoor air temperature sensor open/short
Thermistor or sensor open/short circuit · Loose sensor connector or damaged harness · Sensor out-of-range due to heat/moisture stress · Control PCB sensor input fault
Indoor pipe temperature sensor open/short
Thermistor or sensor open/short circuit · Loose sensor connector or damaged harness · Sensor out-of-range due to heat/moisture stress · Control PCB sensor input fault
Refrigerant absence or severe refrigerant-flow abnormality
Refrigerant shortage due to leak at flare joint or piping · Restriction in expansion valve or refrigerant circuit · Compressor protection triggered by low suction condition
Drainage/full-water-level error
Drain pump not operating or drain path blocked · Condensate tank or drain pan reached full level · Float switch/level sensor abnormality
Communication error between indoor and outdoor units
Loose, reversed, or damaged communication wiring between indoor and outdoor units · Poor terminal contact or corroded wire joints · Indoor or outdoor PCB communication circuit fault · Power instability during operation or after installation
Outdoor pipe temperature sensor open/short
Thermistor or sensor open/short circuit · Loose sensor connector or damaged harness · Sensor out-of-range due to heat/moisture stress · Control PCB sensor input fault
Operating-mode conflict across connected indoor units
Connected indoor units are set to conflicting operation modes · One unit in heating while another is in cooling/dehumidify mode · Mode state mismatch after power recovery in multi-split system
Indoor PCB/control board fault
Indoor control board, fan, or drainage component fault · Loose connectors or internal wiring issue · Drain blockage, float-switch, or pump abnormality · Airflow restriction causing protection trip
Indoor BLDC fan motor lock or fan drive fault
Indoor BLDC fan motor locked or failing · Fan wheel jammed by dirt/debris · Fan motor drive circuit or indoor PCB fault · Wiring harness or connector loosened
Indoor thermistor disconnected/abnormal
Thermistor or sensor open/short circuit · Loose sensor connector or damaged harness · Sensor out-of-range due to heat/moisture stress · Control PCB sensor input fault
Compressor overcurrent / IPM protection
Inverter IPM/power module abnormality · Compressor electrical overload or lock condition · DC link voltage/current abnormality · Power fluctuation causing inverter protection trip
Current sensing value too high (CT protection)
Inverter IPM/power module abnormality · Compressor electrical overload or lock condition · DC link voltage/current abnormality · Power fluctuation causing inverter protection trip
Low DC link voltage in inverter circuit
DC link voltage dropped below safe threshold · Inverter module or capacitor deterioration · Power supply sag or unstable mains voltage
Pressure switch or pressure protection fault
Condenser airflow blocked or outdoor coil heavily dirty · Outdoor fan motor/driver abnormality · Refrigerant pressure or flow imbalance · Outdoor control board protection triggered
AC input voltage abnormal (high/low)
Inverter IPM/power module abnormality · Compressor electrical overload or lock condition · DC link voltage/current abnormality · Power fluctuation causing inverter protection trip
Compressor position/drive abnormal
Inverter IPM/power module abnormality · Compressor electrical overload or lock condition · DC link voltage/current abnormality · Power fluctuation causing inverter protection trip
Power/current sensing circuit fault (PSC)
Inverter IPM/power module abnormality · Compressor electrical overload or lock condition · DC link voltage/current abnormality · Power fluctuation causing inverter protection trip
DC link high-voltage protection
Inverter IPM/power module abnormality · Compressor electrical overload or lock condition · DC link voltage/current abnormality · Power fluctuation causing inverter protection trip
Compressor overcurrent protection
Inverter IPM/power module abnormality · Compressor electrical overload or lock condition · DC link voltage/current abnormality · Power fluctuation causing inverter protection trip
Inverter compressor over-temperature protection
Inverter IPM/power module abnormality · Compressor electrical overload or lock condition · DC link voltage/current abnormality · Power fluctuation causing inverter protection trip
Compressor discharge temperature too high
Condenser airflow blocked or outdoor coil heavily dirty · Outdoor fan motor/driver abnormality · Refrigerant pressure or flow imbalance · Outdoor control board protection triggered
Discharge temperature sensor open/short
Thermistor or sensor open/short circuit · Loose sensor connector or damaged harness · Sensor out-of-range due to heat/moisture stress · Control PCB sensor input fault
High-pressure protection activated
High condensing pressure from blocked outdoor airflow · Outdoor coil heavily soiled or fan underperforming · Refrigerant overcharge or non-condensable gas in circuit
Low-pressure protection activated
Condenser airflow blocked or outdoor coil heavily dirty · Outdoor fan motor/driver abnormality · Refrigerant pressure or flow imbalance · Outdoor control board protection triggered
Compressor discharge temperature protection (outdoor)
Condenser airflow blocked or outdoor coil heavily dirty · Outdoor fan motor/driver abnormality · Refrigerant pressure or flow imbalance · Outdoor control board protection triggered
Low-pressure switch open fault
Condenser airflow blocked or outdoor coil heavily dirty · Outdoor fan motor/driver abnormality · Refrigerant pressure or flow imbalance · Outdoor control board protection triggered
Refrigerant shortage (low gas) detected
Low refrigerant charge from leak in piping or flare joints · Service valves not fully opened after installation/relocation · Refrigerant flow restriction causing low-pressure condition
PCB or CT sensor open/abnormal
Thermistor or sensor open/short circuit · Loose sensor connector or damaged harness · Sensor out-of-range due to heat/moisture stress · Control PCB sensor input fault
Current transformer (CT) sensor open/short
Thermistor or sensor open/short circuit · Loose sensor connector or damaged harness · Sensor out-of-range due to heat/moisture stress · Control PCB sensor input fault
Compressor discharge thermistor open/short
Thermistor or sensor open/short circuit · Loose sensor connector or damaged harness · Sensor out-of-range due to heat/moisture stress · Control PCB sensor input fault
Outdoor air thermistor open/short
Thermistor or sensor open/short circuit · Loose sensor connector or damaged harness · Sensor out-of-range due to heat/moisture stress · Control PCB sensor input fault
Outdoor middle-pipe thermistor open/short
Thermistor or sensor open/short circuit · Loose sensor connector or damaged harness · Sensor out-of-range due to heat/moisture stress · Control PCB sensor input fault
Outdoor suction-pipe thermistor open/short
Thermistor or sensor open/short circuit · Loose sensor connector or damaged harness · Sensor out-of-range due to heat/moisture stress · Control PCB sensor input fault
Compressor discharge-pipe thermistor open/short
Thermistor or sensor open/short circuit · Loose sensor connector or damaged harness · Sensor out-of-range due to heat/moisture stress · Control PCB sensor input fault
Communication error between main and sub PCB
Loose or damaged interconnection cable between indoor and outdoor units · Poor terminal contact or wiring corrosion · Indoor or outdoor PCB communication circuit fault · Power supply instability
Phase/reverse-phase power wiring error
Reverse phase sequence (R/S/T) after electrical work · One supply phase missing at outdoor unit terminal · Incorrect breaker-box wiring to dedicated AC circuit
Outdoor EEPROM or memory fault
Condenser airflow blocked or outdoor coil heavily dirty · Outdoor fan motor/driver abnormality · Refrigerant pressure or flow imbalance · Outdoor control board protection triggered
Condenser/heat-exchanger over-temperature protection
Condenser airflow blocked or outdoor coil heavily dirty · Outdoor fan motor/driver abnormality · Refrigerant pressure or flow imbalance · Outdoor control board protection triggered
Inverter heatsink temperature too high
Inverter IPM/power module abnormality · Compressor electrical overload or lock condition · DC link voltage/current abnormality · Power fluctuation causing inverter protection trip
Condenser pipe sensor open/short
Thermistor or sensor open/short circuit · Loose sensor connector or damaged harness · Sensor out-of-range due to heat/moisture stress · Control PCB sensor input fault
Heatsink temperature sensor open/short
Thermistor or sensor open/short circuit · Loose sensor connector or damaged harness · Sensor out-of-range due to heat/moisture stress · Control PCB sensor input fault
Outdoor BLDC fan motor lock / fan fault
Outdoor fan motor lock or rotor resistance · Fan driver output fault on outdoor PCB · Physical obstruction or severe coil heat load
BLDC fan motor lock protection
BLDC fan motor lock or startup failure · Fan motor feedback (Hall) signal abnormal · Outdoor PCB fan-drive circuit fault
Test-run protection error (installation/piping/power related)
Installation test-run detected piping/refrigerant abnormality · Compressor load protection triggered during commissioning · Temporary power instability during startup
Test-run protection error (installation/piping/power related)
Installation test-run detected piping/refrigerant abnormality · Compressor load protection triggered during commissioning · Temporary power instability during startup
Indoor-outdoor communication instability
Indoor-outdoor communication line instability · Outdoor unit not receiving power on newer split-power models · Wiring/connector fault or communication PCB issue
Indoor floor-standing model system fault (F1)
Model-specific protection or control logic detected abnormal operation · Internal wiring or component fault · Control PCB requires professional diagnosis
Indoor floor-standing model system fault (F2)
Model-specific protection or control logic detected abnormal operation · Internal wiring or component fault · Control PCB requires professional diagnosis
Indoor floor-standing model system fault (F3)
Model-specific protection or control logic detected abnormal operation · Internal wiring or component fault · Control PCB requires professional diagnosis
Condensate tank full / float-level protection
Condensate tank reached full level in high-humidity operation · Drain outlet blocked or drain cap not fitted correctly · Float or level-sensing circuit issue
Room temperature sensing/control abnormality
Thermistor or sensor open/short circuit · Loose sensor connector or damaged harness · Sensor out-of-range due to heat/moisture stress · Control PCB sensor input fault
Not sure how to interpret your LG code?
Share the code and your model sticker. We'll advise your next step before any work is approved.