Hitachi Aircon Error Codes

Learn what common Hitachi error codes mean, what typically causes them, and whether they need urgent attention.

Hitachi code table

This is a guidance table, not a model-exact diagnosis. The same code can differ by series, controller, and model year. Use this page to narrow next steps, then verify with model sticker details.

Safety warning

Stop using the unit and contact a technician if the breaker trips repeatedly, you smell burning, see sparks, hear loud electrical buzzing, or water is leaking from places it normally should not.

Filter by category
01Indoor

Indoor safety device activated

Drain protection or float-switch trigger · Indoor fan or airflow-related protection trip · Indoor control circuit fault

02Outdoor

Outdoor safety/high-pressure device activated

Outdoor high-pressure switch trip · Condenser airflow restriction · Outdoor protection circuit activation

03Communication

Abnormal transmission between indoor and outdoor units

Interconnection wiring fault or poor contact · Communication PCB fault at indoor or outdoor unit · Power disturbance affecting serial communication

05Inverter

Phase signal detection abnormal

Phase pickup/synchronization circuit fault · Inverter board signal processing issue · Power supply waveform abnormality

06Inverter

Inverter voltage abnormal (too low/high)

Undervoltage or overvoltage at outdoor inverter · DC bus voltage instability · Inverter PCB power-stage fault

07System

Discharge superheat control abnormal

Refrigerant flow instability · Expansion control issue · Compressor loading outside normal envelope

08Inverter

Compressor discharge temperature too high

Compressor thermal overload · Poor heat rejection at condenser · Sensor/control drift causing overheating protection

13Sensor

Indoor heat-exchanger liquid-pipe thermistor abnormal

Liquid-pipe thermistor open or short circuit · Loose sensor connector · Indoor PCB input channel fault

14Sensor

Indoor heat-exchanger gas-pipe thermistor abnormal

Gas-pipe thermistor open or short circuit · Sensor harness damage or poor contact · Control PCB thermistor sensing fault

15Sensor

Fresh-air/air-temperature thermistor abnormal

Outdoor/fresh-air thermistor failure · Sensor wiring disconnection · PCB thermistor read error

19Indoor

Indoor fan motor protection activated

Indoor fan motor lock or overload · Fan drive circuit issue on indoor PCB · Wiring/connector fault to fan motor

20Sensor

Compressor discharge thermistor abnormal

Discharge thermistor open or short · Loose thermistor connector · Outdoor control board sensing fault

22Sensor

Outdoor ambient thermistor abnormal

Outdoor ambient thermistor open/short · Sensor connector corrosion or looseness · Outdoor PCB sensor input issue

24Sensor

Evaporating-temperature thermistor abnormal in heating

Evaporating thermistor open or short · Sensor installation or contact issue · Heating-cycle control board sensor error

35System

Incorrect indoor unit number/capacity setting

Indoor-outdoor addressing mismatch · Incorrect combined indoor capacity setup · Installation/configuration error after replacement

38Inverter

Outdoor protective circuit abnormal

Outdoor protection circuit component fault · Inverter board fault · Protection logic triggered by abnormal electrical load

41Outdoor

Cooling overload with high-pressure protection

Condenser airflow restriction · Outdoor fan underperformance · System high-pressure condition during cooling

42Outdoor

Heating overload with high-pressure protection

High refrigerant pressure during heating · Outdoor heat-exchanger airflow limitation · Outdoor fan or control fault

45Outdoor

High-pressure increase protection activated

Rapid pressure rise in refrigerant circuit · Condenser heat rejection problem · Outdoor control/protection trip

47Outdoor

Low-suction-pressure protection active

Very low suction pressure in refrigerant circuit · Refrigerant shortage or restriction · Protection logic activation to prevent damage

48Inverter

Instantaneous overcurrent protection (inverter)

Inverter current spike beyond threshold · Compressor electrical stress · Power module or drive-circuit fault

51Sensor

Current sensor circuit abnormal

Faulty current sensor · Sensor circuit wiring fault · Outdoor PCB current-measurement fault

53Inverter

IPM/transistor module protection activated

Inverter transistor module fault · IPM protection triggered by abnormal load · Outdoor drive circuit abnormality

57Outdoor

Outdoor DC fan motor protection abnormal

Outdoor fan motor output drop or lock · Fan driver fault on outdoor board · Mechanical resistance at fan assembly

B1System

Incorrect unit and refrigerant-cycle number setting

Wrong unit addressing setup · Refrigerant cycle number mismatch · Configuration error after installation or PCB replacement

E0System

EEPROM or indoor control memory error

Corrupted indoor control memory data · Indoor PCB failure · Power interruption during control write cycle

E1Outdoor

High-pressure protection activated

Blocked condenser airflow at outdoor unit · Outdoor fan underperforming or stalled · High refrigerant pressure from overcharge or restriction

E2Indoor

Indoor coil freeze protection active

Restricted indoor airflow from dirty filter or coil · Low refrigerant condition · Indoor fan or thermistor control issue

E3Outdoor

Low-pressure protection activated

Refrigerant leak or undercharge · Refrigeration circuit restriction · Pressure sensor or control fault

E4Inverter

Compressor overheating protection

High compressor thermal load · Poor condenser heat rejection · Compressor or inverter drive abnormality

E5Inverter

Overcurrent protection active

Compressor current draw above limit · Inverter power module stress · Power supply instability

E6Communication

Indoor-outdoor communication error

Loose or damaged interconnection cable · Terminal contact corrosion or loose connection · Indoor or outdoor PCB communication circuit fault

F1Sensor

Indoor temperature sensor fault

Room thermistor open or short circuit · Loose sensor harness connection · Indoor PCB sensor input fault

F2Sensor

Evaporator coil sensor fault

Evaporator thermistor open or short circuit · Sensor wire damage or connector looseness · Indoor PCB sensing circuit issue