Indoor safety device activated
Drain protection or float-switch trigger · Indoor fan or airflow-related protection trip · Indoor control circuit fault
Learn what common Hitachi error codes mean, what typically causes them, and whether they need urgent attention.
This is a guidance table, not a model-exact diagnosis. The same code can differ by series, controller, and model year. Use this page to narrow next steps, then verify with model sticker details.
Safety Warning
Stop using the unit and contact a technician if the breaker trips repeatedly, you smell burning, see sparks, hear loud electrical buzzing, or water is leaking from places it normally should not.
Indoor safety device activated
Drain protection or float-switch trigger · Indoor fan or airflow-related protection trip · Indoor control circuit fault
Outdoor safety/high-pressure device activated
Outdoor high-pressure switch trip · Condenser airflow restriction · Outdoor protection circuit activation
Abnormal transmission between indoor and outdoor units
Interconnection wiring fault or poor contact · Communication PCB fault at indoor or outdoor unit · Power disturbance affecting serial communication
Phase signal detection abnormal
Phase pickup/synchronization circuit fault · Inverter board signal processing issue · Power supply waveform abnormality
Inverter voltage abnormal (too low/high)
Undervoltage or overvoltage at outdoor inverter · DC bus voltage instability · Inverter PCB power-stage fault
Discharge superheat control abnormal
Refrigerant flow instability · Expansion control issue · Compressor loading outside normal envelope
Compressor discharge temperature too high
Compressor thermal overload · Poor heat rejection at condenser · Sensor/control drift causing overheating protection
Indoor heat-exchanger liquid-pipe thermistor abnormal
Liquid-pipe thermistor open or short circuit · Loose sensor connector · Indoor PCB input channel fault
Indoor heat-exchanger gas-pipe thermistor abnormal
Gas-pipe thermistor open or short circuit · Sensor harness damage or poor contact · Control PCB thermistor sensing fault
Fresh-air/air-temperature thermistor abnormal
Outdoor/fresh-air thermistor failure · Sensor wiring disconnection · PCB thermistor read error
Indoor fan motor protection activated
Indoor fan motor lock or overload · Fan drive circuit issue on indoor PCB · Wiring/connector fault to fan motor
Compressor discharge thermistor abnormal
Discharge thermistor open or short · Loose thermistor connector · Outdoor control board sensing fault
Outdoor ambient thermistor abnormal
Outdoor ambient thermistor open/short · Sensor connector corrosion or looseness · Outdoor PCB sensor input issue
Evaporating-temperature thermistor abnormal in heating
Evaporating thermistor open or short · Sensor installation or contact issue · Heating-cycle control board sensor error
Incorrect indoor unit number/capacity setting
Indoor-outdoor addressing mismatch · Incorrect combined indoor capacity setup · Installation/configuration error after replacement
Outdoor protective circuit abnormal
Outdoor protection circuit component fault · Inverter board fault · Protection logic triggered by abnormal electrical load
Cooling overload with high-pressure protection
Condenser airflow restriction · Outdoor fan underperformance · System high-pressure condition during cooling
Heating overload with high-pressure protection
High refrigerant pressure during heating · Outdoor heat-exchanger airflow limitation · Outdoor fan or control fault
High-pressure increase protection activated
Rapid pressure rise in refrigerant circuit · Condenser heat rejection problem · Outdoor control/protection trip
Low-suction-pressure protection active
Very low suction pressure in refrigerant circuit · Refrigerant shortage or restriction · Protection logic activation to prevent damage
Instantaneous overcurrent protection (inverter)
Inverter current spike beyond threshold · Compressor electrical stress · Power module or drive-circuit fault
Current sensor circuit abnormal
Faulty current sensor · Sensor circuit wiring fault · Outdoor PCB current-measurement fault
IPM/transistor module protection activated
Inverter transistor module fault · IPM protection triggered by abnormal load · Outdoor drive circuit abnormality
Outdoor DC fan motor protection abnormal
Outdoor fan motor output drop or lock · Fan driver fault on outdoor board · Mechanical resistance at fan assembly
Incorrect unit and refrigerant-cycle number setting
Wrong unit addressing setup · Refrigerant cycle number mismatch · Configuration error after installation or PCB replacement
EEPROM or indoor control memory error
Corrupted indoor control memory data · Indoor PCB failure · Power interruption during control write cycle
High-pressure protection activated
Blocked condenser airflow at outdoor unit · Outdoor fan underperforming or stalled · High refrigerant pressure from overcharge or restriction
Indoor coil freeze protection active
Restricted indoor airflow from dirty filter or coil · Low refrigerant condition · Indoor fan or thermistor control issue
Low-pressure protection activated
Refrigerant leak or undercharge · Refrigeration circuit restriction · Pressure sensor or control fault
Compressor overheating protection
High compressor thermal load · Poor condenser heat rejection · Compressor or inverter drive abnormality
Overcurrent protection active
Compressor current draw above limit · Inverter power module stress · Power supply instability
Indoor-outdoor communication error
Loose or damaged interconnection cable · Terminal contact corrosion or loose connection · Indoor or outdoor PCB communication circuit fault
Indoor temperature sensor fault
Room thermistor open or short circuit · Loose sensor harness connection · Indoor PCB sensor input fault
Evaporator coil sensor fault
Evaporator thermistor open or short circuit · Sensor wire damage or connector looseness · Indoor PCB sensing circuit issue