Indoor FCU PCB board fault signs

The indoor FCU PCB controls fan logic, reads sensors, and manages core indoor commands. When this board behaves abnormally, symptoms can look wide and inconsistent. Because board replacement can be expensive, checks should confirm this path before you commit.

Quick verdict

Most likely when

  • FCU behavior stays erratic across repeated runs
  • Fan-command response is inconsistent at the same settings
  • Sensor values look normal but control behavior is still unstable

Often not this

  • Thermistor drift causing wrong control decisions
  • Airflow restriction from FCU buildup
  • Loose connectors or wiring contact issues

Check first

  • Sensor accuracy against real thermal behavior
  • Connector and wiring stability at FCU board points
  • Repeatable pattern across more than one run cycle

Primary question

How do I tell whether the indoor FCU PCB is truly faulty before approving replacement?

Where this part sits and what it does

This board sits in the indoor FCU control section.

It manages fan commands, protection logic inputs, and signal interpretation from indoor sensors.

Symptoms this part can cause

Indoor PCB-related issues often appear as unstable command behavior.

  • Indoor fan response is inconsistent for the same settings
  • Cooling behavior feels erratic without a clear mechanical pattern
  • Intermittent behavior that is difficult to reproduce consistently

Common look-alikes before you blame the indoor PCB

Many FCU issues can mimic control-board faults.

  • Indoor thermistor drift or sensor-path issues
  • FCU airflow restrictions from coil/fan barrel buildup
  • Wiring or connector instability at the FCU side

What to check before replacing the indoor FCU PCB

Start with checks that separate board behavior from sensor and airflow problems.

  • Check indoor sensor readings against expected thermal behavior
  • Check connector and wiring stability at FCU control points
  • Confirm the same unstable behavior appears repeatedly before concluding board fault

What to ask your technician to show

Ask for proof that points to the board itself, not only broad symptom descriptions.

  • What specific behavior indicates indoor PCB failure
  • What was ruled out first (sensor, airflow, wiring)
  • Why this points to board replacement now

When to get urgent help

Get urgent help when the unit keeps cycling unpredictably or refuses stable operation after recent service.

Repeated unstable control can lead to recurring downtime and higher repair cost.

When replacement makes sense and when it does not

Replacement usually makes sense when board-level instability remains after sensor, airflow, and wiring checks are complete.

It usually does not make sense when the recommendation is based on one-time behavior without clear exclusions.

Need help with your own unit?

Tell us what is happening. We will assess first, advise one clear next step, and you decide.

Get an Assessment