Aircon Cannot Turn On

A no-start aircon usually points to supply interruption, command-path failure, or control/protection lock behavior. Here is how to separate the pattern quickly.

Before You Read On

Note your answers to these three questions. They take 30 seconds and will point you to the right fault path.

  1. 1Do you see standby lights on the indoor unit?
  2. 2When you start it, do you hear any beep or relay click?
  3. 3Does the breaker remain stable or trip during startup attempts?

What This Usually Means

01

Power-Supply Path Interruption

Most common · Needs diagnosis

Needs diagnosis

If supply is interrupted upstream or unstable, the unit may show no lights, no beep, and no startup reaction.

  • No indicator light at all.
  • No startup beep response.
  • No indoor or outdoor startup sound.

Watch out: Replacing boards before confirming supply-path integrity can create unnecessary cost.

02

Command Path Or Handoff Failure

Standby present but no start · Needs diagnosis

Needs diagnosis

The unit can have standby power but still fail to start when command handoff into control logic is inconsistent.

  • Standby indication exists but no cooling cycle starts.
  • Response is intermittent across attempts.
  • Behavior changes without a stable pattern.

Watch out: Assuming remote failure alone can delay deeper control-path diagnosis.

03

Control-Board Or Protection Lock

Less common · Needs diagnosis

Needs diagnosis

Protection logic can block startup when prior fault conditions persist, and board-level faults can look similar.

  • Unit appears alive but startup does not complete.
  • Short startup attempt then immediate stop.
  • No sustained cycle despite repeated commands.

Watch out: Forcing repeated startups can hide useful pattern data needed for accurate root-cause diagnosis.

Not Always A Fault - Schedule Or Mode Logic Can Block Startup

Timer, sleep, or grouped-control settings can intentionally prevent startup. It feels like hard failure, but the control logic is overriding your command.

How to tell

  • No-start appears at similar times instead of fully random intervals.
  • Other units respond while one specific unit stays blocked.
  • Behavior began after app or scene-setting changes.

If this is the case we will tell you before recommending hardware repair.

What We Find And What Happens Next

FindingNext Step
No standby indicators with no startup responseTrace supply path and isolate interruption point
Standby present but command handoff unstableDiagnose control-path response behavior
Startup attempts but protection lock persistsVerify protection trigger before parts scope
Behavior aligns with timer or mode settingsCorrect control settings and confirm normal start
Pattern remains unclearRetest under normal operating schedule

What To Note Before You Contact Us

No disassembly needed. Just observe:

  • Indicator status: on, off, or intermittent.
  • Startup response: beep, click, brief attempt, or no response.
  • Breaker behavior: stable, trip-on-start, or random trip.
  • Timing pattern: constant no-start or intermittent no-start windows.

The more specific you are, the faster we point you to one next step.

Stop Using The Unit If You Notice These

These are not routine no-start faults. These are safety issues.

  • Burning or electrical smell
  • Repeated breaker trips on startup attempts
  • Sparking or crackling near any unit
  • Water near live electrical points